Related Product
Industrial Multiple PLC Trainer
Model: LA-IMPT-I
Feature:
Multiple PLC Trainer contain nine different reputed PLC where any two PLC does not use same, It have used seventeen extra input and output modules for interfacing Nine different categories PLC. That’s why students can be programming, interfacing with input and output load from nine
different reputed categories PLC.As a result they are capable to control of machinery from industries where use of PLC.
Experiment List:
– The constriction of nine different categories PLC.
– Interfacing method of nine different categories PLC.
– Programming method of nine different categories PLC.
– Pick & Place using PLC & Pneumatic Air Suction method.
– Pick & Place using PLC & Pneumatic Gripper method.
– Water Pump Control using nine different categories PLC.
– Fire Indication System using nine different categories PLC.
– Traffic Light Control using nine different categories PLC.
– The constriction of Pneumatic cylinder.
– Sequential control of three Pneumatic cylinder using nine different categories PLC.
– The constriction of Pneumatic solenoid valve.
– Control of Pneumatic solenoid valve using PLC.
– Interfacing of PLC & Pneumatic solenoid valve.
– The method of Control Relay using PLC.
– The methods of three phase Induction Motor Starter using PLC.
– Forward-and-reverse operation methods of three phase Induction Motor.
– The method of interfacing PLC with Input Switch.
– The method of interfacing PLC with Input Sensor.
– Operating method of interfacing proximity sensor with PLC.
– Operating method of interfacing photo sensor with PLC.
– Use of Variable Frequency Drive with PLC.
– Programming method of Variable Frequency Drive with PLC.
– The construction of Three Phase Induction motor.
– Interfacing Method of Three Phase Induction motor with VFD & PLC.
– The construction of Stepper Motor.
– Interfacing Method of Stepper Motor with PLC.
– The construction Seven Segment Display.
– Interfacing Method of Seven Segment Display with PLC.
– Interfacing Power Supply with nine different categories PLC
Technical Specification:
Main Structure:
– Main Voltage : 1 Phase 220V per 50 or 60Hz
– Working Table: 1EA
– Working Frame – 3 Step
– Module Storage Cabinet : 2EA
– Electric accessories Storage Cabinet : 1EA
– Ari Compressor : 1EA
– Air compressor (basic equipment minimal machine): power: AC 220V(Plus or Minus)10 percent 50Hz or 60Hz,motor power: 650W
– Nominal volume Air compressor: 9L normal output voltage 0.7 MPa, noise degree: 66 dB
– Dimension :L x W x H (mm):1735 x700 x 1660
– Connection facility 2mm & 4mm Safety Socket
PLC Category -01(LA-401A-M01)
-PLC:SIEMENS
-Part Number: 6ED1052-1MD00-0BA8
– Programming Language: Ladder, Functional Flow Chart Diagram
– Built in Ethernet communication
– PLC Power supply: (1 No.)
– PLC Digital Input: 08
– PLC Analog Input: 04 Nos
– PLC Analog Output: 02 Nos
– PLC Digital output: 04
– PLC Display Unit : YES
– PLC Input Voltage: 24VDC, 1Amp
– Permissible range, Lower limit(DC): 20.4V
– Permissible range, Upper limit(DC): 28.8V
– Programming Software: LOGO Soft Comfort or equivalent
– Programming Cable: PLC to PC communication Cable
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Category-02 (LA401A-M02)
-PLC: Mitsubishi
-Parts:FX3U-16MR-DS
– Power Supply: 24VDC
– Input Types:24VDC
– Output Types: Relay
– Communication Options: RS-232 , RS-485, RS-422, USB
– CPU Functions: High speed counters, 32 bit floating point math
– Program Memory Byte (Step): 128 K max. (64,000)
– Ambient Temperature: 0-55 degree C (in operation) -20 (Plus or minus)70 degree C (in storage)
– Ambient Humidity: 5-95percent RH, no condensation (in operation)
– Noise Immunity: 1000 Vpp noise voltage, 1 microsecond pulse width at 30-100Hz
– Digital Input: 8
– Digital Output :8 (Relay)
– Programming Software: Gx-Developer or equivalent
– Programming Cable: SC-09 or equivalent
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Category-03 (LA-401A-M03)
-PLC:Fatek
-Parts:- FBs-14MAR
– PLC input: 8 points Digital
– Triggering Power:24VDC
– (2 points high speed 100KHz, 2 points medium speed 20KHz, 4 points medium
speed total 5KHz);
– PLC Output: 6 points relay
– Communication Port:RS232,USB
– Built-in power supply: SPW14-AC or D12 or D24
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Category-04 (LA-401A-M04)
-PLC:Omron
-Parts: CPM1A-30CDR-A-V1
– Power Supply=220VAC
– Triggering Voltage:24VDC
– Digital Input=18
– Digital Output=12(Relay
– Programming Cable: PLC to PC communication Cable
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Category-05 (LA-401A-M05)
-PLC: Delta
-Parts: dvp10ec00r3
– Power Supply:220VAC
– Triggering Voltage:24VDC
– Digital Input:06
– Digital Output:04(Relay)
– Programming Cable: PLC to PC communication Cable
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Category-06 (LA-401A-M06)
-PLC: Allen Bradley
-Parts No: Micro820
– PLC Digital Input:12 Nos
– PLC Digital Output:07 Nos
– PLC Analog Input:04 Nos
– PLC Analog Output:01No
– 20-point controllers
– Provides embedded 0…10V non-isolated 4 channel analog input and 1 channel analog output for speed control of an AC drive
– Provides embedded communications via non-isolated serial port (for RS-232 and RS-485 communications) and Ethernet port
– Communicates via EtherNet or IP
– Provides embedded microSDTM slot for program transfer, datalog, and recipe management
– Provides embedded support for up to four 10k thermistor temperature inputs
– Supports program download through USB with an optional 3.5-in. Remote LCD
– Supports up to two Micro800 Plug-in Modules
– Programming Cable: PLC to PC communication Cable
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Category-07 (LA-401A-M07)
-PLC: LS
-parts:XBC-DR30SU
– Power Supply=220 V AC
– Digital Input =18
– Digital Output=12(Relay)
– Triggering Voltage:24VDC
– Programming Cable: PLC to PC communication Cable
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Category-08 (LA-401A-M08)
-PLC: Schneider Electric
-Parts: SR3B101BD or AFPX-C40R
– Built in display: LCD
– High-speed Operation
– Number or control scheme lines
– Maximum Number of I & O Points:
– 0…500 with FBD programming
– 0…240 with ladder programming.
– Cycle time : 6…90 ms
– Backup time : 10 years at 25 degree C
– Checks : Program memory on each power up
– Supply voltage limits : 19.2…30 V
– Discrete input voltage : 24 V DC
– Discrete input current : 4 mA
– IP degree of protection : IP20 (terminal block) conforming to IEC 60529
– Mechanical durability : 10000000 cycles (relay output)
– Output thermal current : 8 A for all 4 outputs (relay output)
– Number of outputs : 4 relay output(s)
– Discrete input number : 6 conforming to EN or IEC 61131-2 type 1
– Programming Cable: PLC to PC communication Cable
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Category-09 (LA-401A-M09)
-PLC :Wecon
-Parts: LX3V-0806MR-A2
– Power Supply=220VAC
– Digital Input=8
– Digital Output=6 (Relay)
– Triggering Voltage:24VDC
– Programming Cable: PLC to PC communication Cable
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
PLC Pick & Place using Pneumatic Air Suction Module: (LA-401A-M10)
– Base Plate: Aluminum Profile
– Structure: Aluminum Profile
– Function Indicator: Tower Type (Red, Green, Yellow)
– Carry Function: Using Air suction method
– Pneumatic cylinder: 02 Pcs
– Optical Fiber Sensor:02 set
– Solenoid Vaulve:3 pcs
– Cabinet control circuit power supply: DC24V
– Temperature: -10 to 40 ; Humidity: getter than or equal 90 percent ;
– Air pressure: 0.4 to 0.6Mpa
– Input power : single-phase, three-wire AC 220V(plus minus)10 percent 50Hz or 60Hz
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):600 x 460 x 20
PLC Pick & Place using Pneumatic Gripper Module: (LA-401A-M11)
– Base Plate: Aluminum Profile
– Structure: Aluminum Profile
– Function Indicator: Tower Type (Red, Green, Yellow)
– Carry Function: Using pneumatic gripper method
– Pneumatic cylinder: 02 Pcs
– Optical Fiber Sensor:02 set
– Solenoid Vaulve:3 pcs
– Cabinet control circuit power supply: DC24V
– Temperature: -10 to 40 ; Humidity: greater than or equal 90percent ;
– Air pressure: 0.4 to 0.6Mpa
– Input power : single-phase, three-wire AC 220V plus minus 10 percent 50Hz or 60Hz
– Connection facility 2mm & 4mm Safety Socket
– Module Dimension : L x W x H (mm):600 x 460 x 20
Water Pump Control Module: (LA-401A-M12)
– Base Plate: Aluminum Profile
– Water Chamber: Upper And Lower
– Water through: Solenoid Valve
– Water Pump: 5W
– Operating Voltage : 24VDC
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension : L x W x H (mm):600 x 460 x 20
Fire Indication System Module: (LA-401A-M13)
– Smoke Sensor
– Interfacing PLC and DC power supply Connection facility
– Interfacing facility With water level control Module
– Operating Voltage : 24V
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Traffic Light Control Module:(LA-401A-M14)
– Built-in ,Green, Yellow, Red Indicator for interface PLC and DC power supply Connection facility
– Operating Voltage : 24V
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Pneumatic Control Module: (LA-401A-M15)
– Pneumatic cylinder: 3EA
– Temperature: -10 to 40 ;
– Humidity: greater than or equal 90 percent ;
– Air pressure: 0.4 to 0.6Mpa
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Pneumatic solenoid valve Module: (LA-401A-M16)
– Pneumatic solenoid valve: 3EA
– Operating Voltage : 24V
– PLC connection point : 3EA
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
– Interfacing facility Pneumatic control Module
Relay Control Module: (LA-401A-M17)
– Double pole Double Through Relay: 04 Set
– Relay Operating Voltage:24V
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
–
Motor Starter module: (LA-401A-M18)
– Magnetic Contact switch:02 nos
– Star Delta Status Indication facility
– Relay Operating Voltage:220V to 240VAC
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Input Switch Module: (LA-401A-M19)
– Pushbutton Switch:04 Nos
– Push on Push Off Switch: 04 Nos
– Relay Operating Voltage:24VDC
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Sensor module: (LA-401A-M20)
– Proximity Sensor:02 Nos
– Photo Sensor:02 Nos
– Thermocouplar:02 Nos
– Operating Voltage:24VDC
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Output Indicator Module: (LA-401A-M21)
– Output Indicator:04 Nos
– Operating Voltage:220V~240VAC
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Variable Frequency Drive Module: (LA-401A-M22)
– Variable Frequency Drive:01 No
– Input Three Phase/Single Phase
– Output Three Phase 220VAC (PWM)
– Capacity:400watts
– Input Operating Voltage:220V~240VAC
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Three Phase Induction motor Module: (LA-401A-M23)
– Three Phase Induction Modeule:01 No
– Connection system : Delta
– Input Operating Voltage:220V~240VAC
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Stepper Motor Control Module: (LA-401A-M24)
– Unipolar Stepper Motor:01 No
– Bipolar Stepper Motor:01 No
– Input Operating Voltage:5V/12V
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Seven Segment Display module: (LA-401A-M25)
– Seven Segment Display:02 no
– Input Operating Voltage:5V & 12V
– PLC Connection facility 2mm & 4mm Safety Socket
– Module Dimension :L x W x H (mm):295 x 225 x 45
Power Supply Module: (LA-401A-M26)
– Input Operating Voltage:220V~240VAC
– Output AC Voltage:220V,50Hz
– Output DC Voltage:5V(1Amp),12V(1Amp),24V(1Amp)
– PLC connection point facility 2mm and 4mm Safety Socket
– Fuse for Safety protection facility.
Accessories:
– Air Compressor-01 no
– Connecting jack 2mm & 4mm : 01 Set
– Power Cable: 01 no
– PLC to PC Communication cable: 09 Sets
– Simulation software for compatible PLC
– English Manual & CD: 01 Set
Industrial Automation Training System
Model: ZF-MTS902
General descriptions:
With 6 stations modular production system, mechatronics training includes distributing testing, processing, handling, assembly and storing stations that can be operated separately or integrally. The modular production systems allow varying simulation of real production processes that exist in industry field. The system is universal, industry based, modular and flexible for further expansion. Students can learn the entire process of production such as feeding, processing, etc. Each stations simplifies the training of operation and can be expanded sequentially step by step through building complete automated procedure.
Learning contents:
- Sensors
- Mechanical automation
- PLC program development
- Sequential control
- Installation diagnostic
- Pneumatic
- Drives
- Electronics
- Industrial safety
A. Distributing Station: A double-acting air cylinder pushes work pieces out individually. The cylinder is integrated into a work piece feeding module, cylinder and gravity feed magazine included. This feeder can carry up to six cylindrical work pieces. With a through-beam fiber optic sensor, it can monitor whether the work pieces is placed in the proper position. The handling arm module consists a rotary air cylinder and a mechanism. It moves the work pieces to next station. Two proximity switches detect the positions of the rotary cylinder. Various actuators used in this stations are industrial components. The following modules and components are included.
ZMP1104 - Pneumatics Training System
Feature:
Pneumatic training device is at the request of modern pneumatic professional teaching experiment, according to “the hydraulic and pneumatic transmission ", "The Pneumatic control technology", etc., general teaching material contents design. The system in Addition Meet the base and teaching training system of need of practical applications Equipment structure is firm and has good stability Low noise operation layout clear and intriguing design The four truckle with crack slot in order to move and install on the work table. Panel grooves intervals are 25 mm, can easily move all kinds of components insert on it. Various pneumatic components into separate module which is equipped with bottom panel of elastic pins, when training they can build all kinds of pneumatic circuits on general aluminum, fast loading and unloading, flexible layout, clear pneumatic circuit Electrical control units used for independent relay control unit and multi-button unit control electrical, simple and clear! High safety: have over-current protection, the power supply will cut off as earth leakage exceed 30mA; the electrical control use DC 24v power supply, with over current protection, can prevent damage to the equipment caused by improper operation .system nominal pressure is 0.6MPa
Advanced Sensor Experimental System
Model: SS1102C
Features:
Industrial-standard sensors and transducers With USB interface Open-ended design, ideal for expansion Offer a sensing data acquisition software Specification
Sensor Main Unit
1. Power Supply Unit
Fixed DC power supply
(1) Output voltage : +5V, -5V, +12V, -12V
(2) Max. output current : +5V/3A, -5V/0.3A, +12V/1A, -12V/0.5A
(3) With output overload protection
2. A/D Converter : 1x12-bit ADC
(1) Input voltage range : 0 ~ +5V
(2) Time pulse frequency : 3.58MHz
(3) Control signals : status, pole, over range indication
3. Interface Port USB interface : type B
4. D/A Converter : 1 x 12-bit DAC Analog output& control OUT+ : +DC OFFSET 0 ~ +4.096V unipolar OUT- : -DC OFFSET 0 ~ - 4.096V unipolar OUT BP : DC OFFSET -2.048V ~ +2.048V bipolar
5. Preset Level : 4-digit thumbwheel switch, Max. value : 4095
6. Status Display & DCV Input voltage measurement (1) Range : 2000mV, 20V (2) Accuracy : ±0.05% of reading + 4 counts (3) Input impedance : 10M ohms (4) Display : 4 1/2 digits
7. Mode Selector : manual/single-chip
8. Buzzer : Max. input signal voltage : +12V .
9. Micro Controller Signals : 5 control line outputs
10. Model Holder : X4
11. Potentiometer : 100K ohms B-type
12. Comparator : V-, V+ input, Vo output
13. Differential Amplifier : V-, V+ input, Vo output
Basic Sensor Experimental System
Model: SS1102D
Features
Industrial-standard sensors and transducers With USB interface
Open-ended design, ideal for expansion
Offer a sensing data acquisition software
Specifications:
Main Unit
1. Power Supply Unit
Fixed DC power supply
(1) Output voltage : +5V, -5V, +12V, -12V
(2) Max. output current : +5V/3A, -5V/0.3A, +12V/1.5A, -12V/0.3A
(3) With output overload protection 2. A/D Converter : 1x12-bit ADC (1) Input voltage range : 0 ~ +5V (2) Time pulse frequency : 3.58 MHz (3) Control signals : Status, pole, over range indication 3. Interface Port USB interface : Type B 4. D/A Converter : 1 x 12-bit DAC Analog output & control OUT+ : +DC OFFSET 0V ~ +4.096V unipolar OUT- : -DC OFFSET 0V ~ - 4.096V unipolar OUT BP : DC OFFSET -2.048V ~ +2.048V bipolar 5. Preset Level
Mobile Communication Training System
LabAsia-Model: LA-MT-3000
Technical Specifications:
Ø Full Duplex Voice & Data Communication
Ø Half Duplex Voice & Data Communication
Ø Practice of RF interference & mobile environment
Ø Chatting by using Computer
Ø Board level and full system level experiment is
available using one set
Ø Auto Mode and Manual mode can be selectable
Ø Built-in Software equal to the Commercial Products
Ø Operating like as Commercial Mobile
Ø Products in Auto Mode
Ø 16 x 2 Character LCD
Ø LED Indicator
Ø Over Charge Protection
Ø Communication Method: Full Duplex / Half Duplex
Ø Channel Access: Multi Channel Access
Ø Frequency Range: Base 46.51 ~ 46.97 [MHz], Remote 49.67 ~ 49.99 [MHz]
Ø Output Power: +4.5 [dBm] Max
Ø Channels: 15 Duplex Channels
Ø Bandwidth / Channel: 25 [kHz]
Ø Modulation: FM
Ø Frequency Stability: 5 [ppm]
Ø Receiving Sensitivity: Over 20 [dB] SINAD (at -100 [dBm])
Ø Auto Channel Scan Time: 200 [ms]
Ø Data rate: 2,400 bps
List of Experiments:
Ø Board Unit Module Experiment: Power, Audio, Control, Radio Frequency.
Ø Half Duplex Audio and Data Experiment: Half Duplex Transmitting and Receiving Experiment.
Ø Full Duplex Audio and Data Experiment: Full Duplex Communication Experiment.
Ø Mobile Environmental Experiment: RF Interference Experiment among Systems.
Ø Data Communication: Chatting Practice by Serial Communication.
Training Contents:
Part 1. Introduction of Products:
Ø Experiment 1. Full Duplex Mobile Telecommunications Lab Equipment.
Ø Experiment 2. Power Part
Part 2. Audio Frequency Part:
Ø Experiment 3. Condenser Mike and Limiter
Ø Experiment 4. Compressor
Ø Experiment 5. Pre-emphasis and De-emphasis
Ø Experiment 6. Expander
Ø Experiment 7. Band-Pass Filter and Squelch Circuit.
Part 3. Radio Frequency Part:
Ø Experiment 8. PLL Oscillator
Ø Experiment 9. PLL Oscillator
Ø Experiment 10. Transmitting Part
Ø Experiment 11. Receiving Part
Part 4. Control Part:
Ø Experiment 12. Microcomputer and Key Matrix Control Peripheral Circuits
Part 5. Full Duplex Communication
Ø Experiment 13. Half-Duplex Transmitting Integration Experiment
Ø Experiment 14. Half-Duplex Receiving Integration Experiment
Ø Experiment 15. Full-Duplex Integration Experiment
Ø Experiment 16. Radio Environment Experiment
Ø Experiment 17. Chatting by using Serial communication
Components:
Ø Mobile Set: 1no
Ø Carriage Bag: 1 no
Ø Handset: 2 nos.
Ø Adapter: 2 nos.
Ø Base Set: 1 no
Ø Manual/Textbook: 1 no
Ø Program CD (Multimedia CD): 1 no
Ø RS-232C Cable: 2 nos.
Inverter Experimental Trainer
Model: ST1116
Specification:
Output Characteristic ·
Max Output Voltage : 230V · Rating Output Frequency : Max 400Hz · Rating Output Ampere : 4.8A · Max Continuous Out Ampere : 5.4A · Output Capacity : 2.1 kw _ Power · Voltage & Frequency -3ǫ200/208/220V 50Hz -200/208/220/230V 60Hz · Allowable Voltage Fluctuating : 10% · Allowable Frequency Fluctuating : 10% _ Control Characteristic · Frequency Control Range : 0.1~400Hz · Frequency set Resolving Power -Digital : 0.01~0.1Hz, Analogic : 0.06/60Hz · Output Frequency Resolving Power : 0.01Hz · Frequency Setting Signal : DC 0~10V, DC 4~20mA · Accelerating & Decelerating Time : 0.1~6,000 Sec · Control Characteristic : Sine Wave PWM Type _ Protective Function · Motor Protective : Protective Terms of Electronic Thermal · Instantaneous Over Current : About 200% · Over Voltage : Main Circuit DC Voltage About 400V
Basic Sensor Experimental Lab
Model: LA-BSEL-I
Technical Parameter :
Hydraulic operation station:
It consists of aluminum material profile,
Experiment table dimension : 1600(length)×750(width)×1780(height)mm
Aluminum panel dimension: 1200(length)×600(width)
Groove gap:25mm
Aluminum wood cabinet:1 piece
Caster with crack groove:4 pieces
Groove plate insert and extract system
Hydraulic components
Hydraulic pump station
(a). Work power: AC:380~400V
(b). Frequency: 50Hz
(c). Safety speed limit range: 1000-1500 r/min
(d). Power: 1.5KW
(e). Flow :6L/min
Electrical control module:
Power module: with three phrase leakage protection, output voltage:380V
Dc power module: output voltage DC24V
Rated current: 5A
Button module: signal light power: DC24V
Contact capacity AC220V/1A DC24V/2A
Machine electric life span: one million times
Relay module: coil voltage:DC24V;
Contact capacity:AC240V/10A/ DC24V/10A
Mechanism life: one million times
Proportion shuttle valve amplifier
Power: DC24V
Control voltage:±9V±2﹪
Max output current:1800Ma
Ramps time:0.02s-5s
Proportion relieve valve amplifier:
Power:DC24V
Rated current:800mA
Control range: DC0~+5V or DC0~+10V
Experiment contents:
Basic electric control
a) Lights on control
b) Lights out control
c) And logic control
d) Or logic control
e) Logic combination control
f) Relay self-lock control
g) The usage of proximity sensor
Hydraulic control circuit
1.Direction control circuit
a) manual shuttle valve reversing circuit
b) solenoid valve reversing circuit
c) lock circuit
2.Pressure control circuit
a)Single grade pressure regulating circuit
b) Secondary level pressure regulating
c) Single pressure reducing circuit
d) Level 2 pressure circuit
e) The unloading circuit using “M” “H” type manual shuttle valves
f) The unloading circuit using pilot relief valve
g) The balance circuit using the sequence valve
h) Liquid control one-way valve pressure maintenance.
i) The one-way back pressure circuit using relief valve
3.The flow speed regulator circuit using throttle valve
a) Enter oil-way throttle speed regulation
b) Back oil-way throttle speed regulation
c) Side oil-way throttle speed regulation
4.The speed regulator circuit using speed regulator valve
a) Enter oil-way throttle speed regulation
b) Back oil-way throttle speed regulation
c) Side oil-way throttle speed regulation
d) Speed synchronous circuit of the speed regulation valve
e) The parallel circuit of speed regulation valve
5.Fast moving circuit of hydraulic cylinder differential connection
6.Fast moving circuit of hydraulic cylinder differential connection
7.Sequence action circuit using sequence valve
8.Sequence action circuit use stroke switch control
9.Sequence action circuit use pressure relay control
10.One-way atresia circuit use hydraulic control one-way valve
11.Double-way atresia circuit use hydraulic control one-way valve
12. The lock circuit using O type shuttle valve
13.Relay control hydraulic basic circuit
Proportion hydraulic circuit experiment
1. Proportion amplifier principle
2. Proportion amplifier application
3. Magnetic proportion shuttle valve application
4. Hydraulic motor speed control
5. Hydraulic motor reversal control
Accessories:
– Hydraulic oil Compressor-01 no
– Connecting jack 2mm & 4mm : 01 Set
– Power Cable: 01 no
– PLC to PC Communication cable: 09 Sets
– Simulation software for compatible PLC
– English Manual & CD: 01 Set
Hydraulic Training System
Model : LA-HTS-I
Technical Parameter :
Hydraulic operation station:
It consists of aluminum material profile,
Experiment table dimension : 1600(length)×750(width)×1780(height)mm
Aluminum panel dimension: 1200(length)×600(width)
Groove gap:25mm
Aluminum wood cabinet:1 piece
Caster with crack groove:4 pieces
Groove plate insert and extract system
Hydraulic components
Hydraulic pump station
(a). Work power: AC:380~400V
(b). Frequency: 50Hz
(c). Safety speed limit range: 1000-1500 r/min
(d). Power: 1.5KW
(e). Flow :6L/min
Electrical control module:
Power module: with three phrase leakage protection, output voltage:380V
Dc power module: output voltage DC24V
Rated current: 5A
Button module: signal light power: DC24V
Contact capacity AC220V/1A DC24V/2A
Machine electric life span: one million times
Relay module: coil voltage:DC24V;
Contact capacity:AC240V/10A/ DC24V/10A
Mechanism life: one million times
Proportion shuttle valve amplifier
Power: DC24V
Control voltage:±9V±2﹪
Max output current:1800Ma
Ramps time:0.02s-5s
Proportion relieve valve amplifier:
Power:DC24V
Rated current:800mA
Control range: DC0~+5V or DC0~+10V
Experiment contents:
Basic electric control
a) Lights on control
b) Lights out control
c) And logic control
d) Or logic control
e) Logic combination control
f) Relay self-lock control
g) The usage of proximity sensor
Hydraulic control circuit
1.Direction control circuit
a) manual shuttle valve reversing circuit
b) solenoid valve reversing circuit
c) lock circuit
2.Pressure control circuit
a)Single grade pressure regulating circuit
b) Secondary level pressure regulating
c) Single pressure reducing circuit
d) Level 2 pressure circuit
e) The unloading circuit using “M” “H” type manual shuttle valves
f) The unloading circuit using pilot relief valve
g) The balance circuit using the sequence valve
h) Liquid control one-way valve pressure maintenance.
i) The one-way back pressure circuit using relief valve
3.The flow speed regulator circuit using throttle valve
a) Enter oil-way throttle speed regulation
b) Back oil-way throttle speed regulation
c) Side oil-way throttle speed regulation
4.The speed regulator circuit using speed regulator valve
a) Enter oil-way throttle speed regulation
b) Back oil-way throttle speed regulation
c) Side oil-way throttle speed regulation
d) Speed synchronous circuit of the speed regulation valve
e) The parallel circuit of speed regulation valve
5.Fast moving circuit of hydraulic cylinder differential connection
6.Fast moving circuit of hydraulic cylinder differential connection
7.Sequence action circuit using sequence valve
8.Sequence action circuit use stroke switch control
9.Sequence action circuit use pressure relay control
10.One-way atresia circuit use hydraulic control one-way valve
11.Double-way atresia circuit use hydraulic control one-way valve
12. The lock circuit using O type shuttle valve
13.Relay control hydraulic basic circuit
Proportion hydraulic circuit experiment
1. Proportion amplifier principle
2. Proportion amplifier application
3. Magnetic proportion shuttle valve application
4. Hydraulic motor speed control
5. Hydraulic motor reversal control
Accessories:
– Hydraulic oil Compressor-01 no
– Connecting jack 2mm & 4mm : 01 Set
– Power Cable: 01 no
– PLC to PC Communication cable: 09 Sets
– Simulation software for compatible PLC
– English Manual & CD: 01 Set
Automatic Storage and Sorting Trainer
Model:LA-ASST-I
Technical Parameter :
Base Plate: Aluminum
Function Start, Stop Switch & Emergency Switch
Conveyer Belt Size: 540mm – 560mm
Number of Conveyer Belt: 02 Set
Pneumatic Cylinder. 0 Pcs
Pneumatic motor: 01Pcs.
Capacity of motor: 0.15-0.7Mpa (Mega Pascal, Rotation:180°)
Optical Fiber Sensor:02 Nos
Magnetic Proximity Sensor:19 Nos
Solenoid Valve: 5 Nos
Warehouse Limit Switch: 21 nos
HMI: Display units of warehouse
HMI Display Size: 7 inch
Tray Movement 3 axis (X,Y,Z)
X-axis movement: 30 inch
Y-axis movement: 4.5 inch
Z-axis movement: 15 inch
Cabinet control circuit power supply DC24V ,3Amp
Temperature: 10-40: Humidity: ≤90%
Air pressure: 0.4-0.6Mpa
Machine capacity: ≤0.5KVA
Over Load Current Protection
Earth Lickage Protection
Input Power : Single Phase, Three wire AC
220v ±10%, 50.60Hz
PLC with Expansion Module :
Main Supply: Single Phase, 220v ±10%, 50.60Hz
PLC Input: 54
PLC Output: 10 Nos (Relay)
Analog Output: 02 Nos
Communication Port: 2 nos (RS-232)
PLC Output Relay Type
Operating Voltage: DC 24V
PLC Programming Language: Ladder , Functional Flow Block Diagram
PLC Software operating system: XP, Windows 7, Windows 8

AquaArm_Proof-IWP-10
(Formerly known as MYK Proof WP10)
Chloride Free Integral Liquid Waterpro Admixture for Concrete and Mortar
AquaArm Proof IWP-10 is a chloride free liquid based on selected sugar reduced Ligno Sulphonates.
AquaArm Proof IWP-10 waterproofs by improving the quality of the Concrete or Mortar. It reduces the water demand for required workability and minimizes segregation and bleeding. It is in liquid form and shows excellent dispersion and is more efficient compared to traditional powder water proofers.